| Floor Mount Dragout Systems have the advantage of a low profile so there is no need for a pit. These large systems combine two methods of removing impurities from coolant: the dragout conveyor in the settling tank and the Encyclon cyclonic filter. These two methods work together to filter the dirtiest coolant to 5 microns. Heres how the system works: Dirty coolant from your machines is returned to the dragout tank, where large, heavy particles settle out by gravity. A moving drag flight conveyor sweeps the tank bottom, carries these particles out of the dragout tank and deposits them in a swarf container, leaving coolant free of any large particles. The conveyor has three important features to insure trouble-free operation: An adjustable timer provides exact control (continuous or intermittent) to suit any application. A unique, self-cleaning wiper blade discharges all contaminants into a swarf cart. No particles can be returned to the settling tank. A built-in safety clutch automatically actuates a switch, stopping the conveyor and energizing a trouble light if extremely heavy resistance is encountered by the conveyor. Recommended Use: As a central coolant system. For use with single or multiple machine tools generating large quantities of swarf. |
||||||